100kW~10000kW Air Cooled AC 3 Phase Resistive Load Bank for Generator UPS Power Plant Load Testing 100kW~10000kW Air Cooled AC 3 Phase Resistive Load Bank for Generator UPS Power Plant Load Testing 100kW~10000kW Air Cooled AC 3 Phase Resistive Load Bank for Generator UPS Power Plant Load Testing 100kW~10000kW Air Cooled AC 3 Phase Resistive Load Bank for Generator UPS Power Plant Load Testing 100kW~10000kW Air Cooled AC 3 Phase Resistive Load Bank for Generator UPS Power Plant Load Testing
Next

100kW~10000kW Air Cooled AC 3 Phase Resistive Load Bank for Generator UPS Power Plant Load Testing

FOB Price

Get Latest Price

2450 ~ 220000 / Set

|

1 Set Minimum Order

Country:

China

Model No:

RT100~10000kWLB

FOB Price:

2450 ~ 220000 / Set Get Latest Price

Place of Origin:

China

Price for Minimum Order:

2450 per Set

Minimum Order Quantity:

1 Set

Packaging Detail:

Wrapping film

Delivery Time:

25-30 days

Supplying Ability:

5 Set per Month

Payment Type:

L/C, T/T

Product Group :

Contact Now
Free Member

Contact Person Mr. Winston

East Section of Hongyu Road, Jinshan Industrial Park, Luojiang District, Deyang City, Sichuan Provin, Deyang, Sichuan

Contact Now

Product Specification

  • Color:RAL 7035/ Customer supply color number
  • Nominal voltage:AC380V/400V/415V/480V/690V/10.5KV/11KV/Customized
  • Nominal power:100kW~10000kW
  • Frequency:50/60Hz
  • Power factor:1.0
  • Control mode:Manual/PC control(support printing)

Product Description

**0kW~****0kW Air Cooled AC 3 Phase Resistive Load Bank for Generator UPS Power Plant Load Testing



Following is ***0kW resistive load bank data sheet for example:








































































































 

Model No. RTZ****0kW***0V**0Hz/*0Hz-PF1.0
Load type **0%Resistive
Voltage AC**0V(AC**5V/**0V/**0V/*1KV OR OTHERS)
Frequency *0Hz
Capacity ***0kW
Power factor 1.0
Control mode Two options for selection

 Local panel manual control: The load bank is equipped with a local control panel and is divided into several power steps, which can be loaded through switch control.

 Manual + PCcontrol: control the load through the data management software on the computer,realize all test functions,display,record and manage test data,generate various curves,charts and test reports and support printing.

 Software language: English/or others

PC control system:

 I5 processing system

 *0m category 6 network cable

 Interface:RJ*5/RS**2/**5
Application environment Two options for selection

Indoor(IP*3)

Prevent the invasion of solid foreign objects with a diameter greater than *2.5mm (prevent human fingers from touching the parts inside the appliance, prevent the invasion of foreign objects with a diameter greater than *2.5mm), and prevent the invasion of sprayed water (prevent rain or damage caused by the invasion of water sprayed in the direction with a vertical included angle less than *0 °)

Outdoor(IP*5)

Prevent external objects and dust (completely prevent the invasion of foreign objects, although not completely prevent the invasion of dust, but the amount of dust invasion will not affect the normal operation of electrical appliances), and prevent the invasion of sprayed water (continuous low pressure water spray, 3 minutes)
Control voltage 3P 4 wire,AC*00V
Load accuracy ±3%
3Phase Balance Unbalance≤3%
Insulation F
Power source connection Load power source connection: copper bar
Control power source connection: terminal
 A,B,C,N Will be marked on the product.

Terminal: from left to right: A,B,C,N too.
Time rating Continuous design/temporary
 

Resistive load
Min.step: Nominal1kw resolution or customized

Steps:1kW,2kW,2kW,5kW,*0kW,*0kW,*0kW,*0kW,**0kW*9

Customized available,for example:**0kW**0 or others choice.
Electrical performance index offinned resistor:

Each resistance element: insulation impedance DC***0V/*0MΩ 

Withstand voltage AC ***0v for 1 minute

Resistance error of each resistor: ±3%

■ Long time work under **0℃

■ Temperature drift coefficient:±1.5%

■ Work temperature is 1/3 of the design temperature. 
Cooling system Cooling mode: Forced ventilation,horizontal air inlet/outlet 
■ Airflow/Fan power and air volume shall be designed according to 2 times surplus coefficient of heat loss.  

■ Brand:first-line well-known brand at domestic and abroad

■ Power supply mode: 3phase AC power supply.

■ Noise:≤ *5db (3M)

 The fan adopts axial flow fan, aviation aluminum fan blade, decentralized air supply design, sufficient air volume, low noise, high strength, corrosion resistance, durability and other advantages of the fan blade .
Load test functions ■ Real time display of current

■ voltage

■ frequency

■ power

■ power factor

■ electrical performance indicators

■ curve and report output

■ system electrical parameter monitoring

■ automatic data acquisition

① Above all functions for manual + PC control

② Above functions marked in yellow for manual control            
Data save Manual + PC control: table saved byexcel,curve save by word.Support printing.
Load protection/function ■ Low air volume: when the air volume of any fan is insufficient, it will automatically unload and alarm.

■ High temperature: automatically unload and alarm when the load temperature exceeds the safety threshold.

■ Over voltage: it will automatically unload and alarm when the load

voltage exceeds the safety threshold.

■ Fan interlock protection: the load cannot be loaded before the fan power switch is turned on.

■ Short circuit/over current: the load circuit is equipped with a fuse to avoid damage to the equipment in case of load short circuit or excessive current.  

■ Emergency stop: manual one forced unloading is available, and it cannot be loaded under emergency stop locking status.

■ Fan phase sequence automatic transfer protection: when the control power line is not connected according to the correct phase sequence, the three-phase fan can also operate in the normal direction.

 Protection switch: some protection functions are equipped with switches, and corresponding protection functions can be temporarily turned off in case of false alarm or special needs.

 Grounding protection: in order to avoid electrification of the chassis and electric shock hazard, the load cabinet is equipped with special grounding protection terminals.

 Operational indicator: indicates whether the device can be put into load, and the indicator light on indicates that the device is in normal state and can be put into load.

 Fan operation indicator: indicates whether the fan of the device is running, and the corresponding indicator light for fan startup is on.

 Load switch: the control device is to switch on or off the load, and jog the switch to switch on the selected load.
Cabinet color RAL***5 /Customized(supply thecolor number,for example RAL***8). 
Transportation Lifting hole/ Castors / Forklift hole 
Size/Weight ***2****0****5(mm)  /  ***0kg

Country: China
Model No: RT100~10000kWLB
FOB Price: 2450 ~ 220000 / Set Get Latest Price
Place of Origin: China
Price for Minimum Order: 2450 per Set
Minimum Order Quantity: 1 Set
Packaging Detail: Wrapping film
Delivery Time: 25-30 days
Supplying Ability: 5 Set per Month
Payment Type: L/C, T/T
Product Group : Resistive Load Bank